Standard features
-MID 006 approved for gravimetric filling device
-Aluminum housing with stainless steel front and back panel
-60000d readability
-Total & statistical report
-16 receipt memories
-Automatic preact correction
-Filling process can be followed
-Date, time, and filling or weighing values are exported automatically after each filling
Filling modes
-9 standard filling modes can be selected in programming parameters:
-Liquid filling for open containers, filling under bung hole or at bottom filling
-“Weigh in and emptying” mode for automatic packing
-Tank/Silo filling and discharging
-“Weigh in-Weigh out” for sticky /viscous materials
-Discontinuous totalizers
-Filling in the bag as gross or net
-Bag filling from hopper scale
-Customized filling modes for OEMs' requests.
System integration
-2. serial port RS-232C, RS-485 or 20mA CL ASCII
-Ethernet TCP / IP
-Modbus RTU / TCP
-Profibus
-Profinet
-CANopen
-Additional 4 / 8 paralel I / O
Accuracy class | III |
EU type approved | 10.000 increments (Single range) |
Linearity & temperature coefficient | % 0.0015 FS ; ≤ 2 ppm/°C |
Display | 6 digits, 7 segments, LED red, 20 mm high (Panel type 14 mm high) |
Status annunciators | Gross, net, motion, zero, information, power, unit and 6 LED’s for application related status |
Keyboard | 18-key membrane, with tactile feedback |
Type | 24 bit Delta-Sigma ratiometric with integral analog and digital filters |
Conversion rate | Up to 400 measurements per second |
Maximum 200 measurements per second | 0.4 V per interval legal for trade; 0.1 V per interval non approved |
Analogue input range | 0 mV – 18 mV |
Resolution | Internal up to 8 000 000; display up to 60 000 counts |
Calibration | Calibration is performed by etalon weights |
Digital filter | 10 step adjustable digital adaptive filter |
Excitation | 5 VDC, max. 100 mA |
Number of load cells | Up to 6 load cells (350 ) or 18 load cells (1100 ) in parallel |
Connection | 4 or 6 wire technique. Cable length 274 m/mm² for 6 wire connection |
Operation temperature & humidity | -10 °C to +40 °C legal for trade; 85% RH max, non-condensing |
Enclosure | Panel type ( front panel IP65 ) or stainless steel housing (IP65) |